S. Graffi, A. Peretz, H. Jabaly and M. Naftali
January 2004
E. Gilad, I. Bahar, B. Rotberg and D. Weinberger

Background: Corneal erosions, a common and very painful ailment, are traditionally treated with pressure patches and antibiotic ointment but the healing is slow.

Objectives: To report our experience with the use of therapeutic contact lenses for the primary treatment of traumatic corneal erosions.

Methods: During the last 5 years in a single community clinic 65 consecutive patients with traumatic corneal erosions were treated with a corneal contact lens and antibiotic drops as a routine measure. The charts were reviewed for outcome, side effects and complications.

Results: Healing of the corneal erosions occurred within 1 to 3 days in all patients, with minimal or no pain. No corneal infection occurred. One patient had a recurrence that was successfully treated by lens placement.

Conclusions: The therapeutic contact lens with antibiotic drops is a safe and effective method to treat traumatic corneal erosions, and patients can immediately resume their regular activities.

October 2000
Valentin Fulga MD, Ben-Ami Sela PhD and Michael Belkin MA MD

Background: Most corneal damage induced by contact lenses is due to interference with corneal oxygenation.

Objective: To investigate the effect on the rabbit cornea of a rigid gas-permeable contact lens with a newly designed periphery.

Method: We fitted New Zealand white rabbits (n=12) with RGP[1] contact lenses that were identical in all respects except for the design of the periphery. In each animal, one contact lens had an innovative periphery consisting of a microscopic diffractive relief lathed on the back surface; the other contact lens was of a conventional design. The lenses were worn continuously for 7 days. During this experimental period and for 1 additional week we assessed the corneal damage by daily testing lactic dehydrogenase activity in the tears.

Results: On the last day of the experimental week and the first 3 days of the healing period, mean tear LDH[2] activity was significantly lower in the eyes with the new contact lens design than in eyes with the conventional lenses.

Conclusions: The novel periphery design reduces corneal damage resulting from contact lens wear, as reflected by LDH levels in the tears. The new design probably facilitates the flow and exchange of tears under the contact lens, resulting in improved metabolism of the cornea. These findings may also prove applicable to soft contact lenses.






[1] RGP = rigid gas permeable



[2] LDH = lactic dehydrogenase


Michael Blumenthal, MD and Moshe Schwartz, OD